The Miniature Data Acquisition
System With Maximum Options
|
|

|
Low cost. Most competitive cost
per channel available |
|

|
Light Weight Compact Design.
Under 1.7 kg
per 24 channel unit! |
|

|
Accurate 24-bit recording
system |
|

|
Suitable for most seismic
surveys. Multiple Units can be used at same
time |
|

|
Rugged Aluminum Alloy
Construction |
|

|
Operational modes:
Centralized or Autonomous. Can be used with or without
PC |
|

|
Basic Software Package
Included. Use
your own Notebook or other PC as Data Collection
Unit |
|

|
DC response and automatic DC
removal for use with geophones or
accelerometers |
|

|
Battery and self-triggering
option for:
- Structural Vibration Monitoring
- Earthquake Monitoring
- Micro-Seismic studies
| |

|
|

|
Records all data to internal non
volatile storage card |
|

|
Automatically sends data to
computer over network telemetry |
|

|
Wireless option for remote data
downloads |
|

|
GPS interface for position and
accurate timing reference |
|

|
Uses standard network telemetry
for maximum flexibility |
|

|
Extremely low Power
consumption | |

|
Options Include:
|

|
Integrated GPS
receiver |
|

|
Flash memory Card up to 2GB (32MB
Standard) |
|

|
Remote Wireless
Operation |
|

|
Customized Cable input
Connectors |
|

|
Complete System Configuration
(Record Data the same day you receive System) |
|

|
Continuous Recording
Option |
DAQLink II General Specifications:
Analog
Specifications:
| |
Option
1 |
Option
2 |
|
Maximum Input Signal |
+/- 12 volt gain = x1 |
+/- 1.2 volt gain =
x1 |
|
Input Impedance |
>10 MOhm, 20
picofarad |
10 KOhms |
|
Preamplifier Gain |
x1, x10, x100, x1000 |
x1, x10,
x100 |
Digital
Specifications:
|

|
Resolution |
|
24-Bit |
|

|
Channels per box |
|
6 - 24 (Simultaneous
sampling) |
|

|
Channels per system |
|
Multiple boxes for high channel
count |
|

|
Sample rate |
|
8, 4, 2, 1 msec, 500, 250, 125
usec |
|

|
Input Pre-Amp Gain |
|
x1, x10 or x100 |
|

|
Max Input Voltage |
|
25 Vp-p - Accelerometer
option,
2.5 Vp-p - Geophone option |
|

|
Bandwidth |
|
DC to 4 kHz (Accelerometer
Option) |
|

|
Dynamic Range |
|
144 dB system, 115 dB
measured |
|

|
Common Mode Rejection |
|
> 100 dB |
|

|
Pre-trigger
capability |
|
Up to 32000
samples |
|

|
Long record lengths |
|
>3600 sec |
|

|
Int. Storage Capacity |
|
CF card 32MB to
2GB |
|

|
Output Data Format |
|
Standard SEG-Y, SEG-2 or
ASCII |
|

|
Automatic event capture
capability |
|
|
|

|
Wireless option |
|
Data can be downloaded and
acquisition started via a Wireless Network |
|

|
Miscellaneous |
|
Geophone or Accelerometer test
option |
|

|
Power |
|
10-36 VDC |
|

|
Dimensions |
|
3 x 5.6 x11 in (76 x 144 x 280
mm) |
|

|
Weight |
|
3 lbs (1.4
kg) |
Downloads:
| |
|
 |
Allows Multiple DAQLinks to be
easily connected via a wired network
|
Includes all recording features
of the DAQLink II recorder
Distributed DAQLink includes the following
- DAQLink II recorder module; 6, 12 or 24
channels/box
- Ethernet switch
- Ethernet Line Driver, up to 5000 feet
(1524 m) between boxes
- Standard DAQLink interface connectors, plus two 6-pin digital
communication connectors
Communication
Cable
- One pair for digital data
- One pair for trigger
Trigger input from
source can be connected to any Distributed DAQLink
Computer can be connected to any
Distributed DAQLink unit
Multi-line
Box Interface available for communications with multi-line 3-D
layouts
|
Downloads:
| |