Geophone
| GS-100 |
| gs-100.html |
GS-100![]() |
![]() |
| Feature Small size, lightweight High sensitivity, high output Clean response to 600 Hz Full one year warranty |
| General Description The GS-100 is a high frequency, high output geophone with a natural frequency of 100 Hz. It has a clean band pass and minimum spurious response to 600 Hz. Standard coil resistances are 600, 975, 1550 and 2300 ohms. Open circuit damping is 60% of critical. The PC-21 Land Case is used with the GS-100 geophone. |
| Specifications Natural Frequency : 100 Hz } 10% Maintains Specifications : Up to 90 Tilt } 12% Typical Spurious Frequency : To 600 Hz Standard Coil Resistance @ 25C : 600, 975, 1550, 2300 ohms } 5% Intrinsic Voltage Sensitivity with 600 Ohm Coil : 0.91 V/in/sec (.36 V/in/sec) } 10% Normalized Transduction Constant (V/in/sec) : 0.037 (sq.root of Rc) Open Circuit Damping } 16% : 60% of critical Moving Mass : 6 g } 5% Typical Case to Coil Motion P-P : 0.02 in (.05 cm) Harmonic Distortion with driving velocity of .7 in/sec (1.8 cm/sec) P-P : 0.2% or less at 100 Hz, 0.316 Shunt Resistance for Damping Calibration for 395 ohm coil : 60% damping } 2%: 1500 ohms Dimensions : Height (less terminals*) : 1.38 in (3.50 cm) Diameter : 1.25 in (3.18 cm) Weight : 4.4 oz (125 g) * terminal height is .12 in Chart for Seismic Detector Response Curve Output VS. Frequency (GS-100 @ 600 Ohms & GS-100 @ 1550 Ohms, GS-100 @ 2300 Ohms). Cases Available PC-21 Land Case Specifications are subject to change without notice. |