Geophone

GS-30CT & GS-32CT
gs3032ct.html


GS-30CT
Feature

IThe GS-30CT represents the ultimate refinement in
geophone design to date. This new geophone is
offering heretofore unattainable geophone-to-geophone
uniformity, distortion reduced by a factor of 2.5 and
tighter tolerance on geophone parameters:

New standard } 2%

Channel-to-channel uniformity and elimination of
self-generated noise and distortion is the essence of
seismic data. Towards this end, the performance of the
GS-30CT is clearly unsurpassed. It is a field-proven
match for the most advanced 24-bit Data
Acquisition Systems.
3 Year Warranty
Specifications

Specifications calculated at 25C. Orientation is Vertical to 20. Maintains all specifications at Vertical to 20 tilt. Exception: Harmonic Distortion at 12 Hz (Vertical only).

Frequency :

Natural Frequency (Fn) : 10 Hz } 2%

Typical Spurious Frequency : > 160 Hz

Resistance :

Standard Coil Resistance : 395 ohms } 2%

Distortion :

Harmonic distortion with coil to case velocity of 0.7 in/sec (1.8 cm/sec) @ 12 Hz and coil to case displacement of 0.0093 in (0.0236 cm) P-P @ 12 Hz : <0.08%

With coil to case displacement of 0.0093 in (0.0236 cm) P-P @ 12 Hz : <0.12%

Sensitivity :

Intrinsic Voltage Sensitivity (G) : 0.698 V/in/s, 0.275 V/cm/s

Sensitivity @ 70% Damping : 0.500 (V/in/sec), (.197 V/cm/sec)} 2%

Normalized Transduction Constant : 0.0351 sq.root of DCR; V/in/s 0.0138; sq.root of DCR; V/cm/s

Damping :

Open Circuit Damping (Bo) : 0.316

Shunt Resistance for Damping Calibration for 395 ohm coil : 60% damping } 2%: 1500 ohms, 70% damping } 2% : 1000 ohms

Damping Constant (BcRt) 536

Physical Specifications

Moving Mass (M) : 0.395 oz., 11.2 g } 2%

Case to Coil Motion P-P: 0.060 in (.152 cm)

Operating and Storage Temperature : -45C to +100C

Dimensions (less terminals*) :

Height 1.30 in (3.30 cm)

Diameter 1.00 in (2.54 cm)

Weight 3.03 oz (86 g)

* terminal height is .16 in (.41 cm)

Cases Available:
PC-801-LP Land Case
PC-801-LPC Land Case
PC-901-LP Marsh Case

Specifications are subject to change without notice.

Chart for Seismic Detector Response Curve Output VS. Frequency.


GS-32CT
GS-32CT
Features

Spurious response greater than 250 Hz for extended clean band width

Full compatibility with GS-20DX and GS-30CT geophones

Typical string distortion less than .03% (12 series, damped .70)

High sensitivity option available

3-Year Warranty
Specifications (At 25 C)

Maintains all specifications at vertical to 20 tilt with the following exception : Harmonic distortion at 12 Hz (vertical to 10 tilt).

Natural Frequency (Fn) : 10 Hz }2.5%
Coil Excursion P-P : > 0.040 in( > 0.102 cm) MIN, > 0.060 in, (> 0.152 cm) MAX

Clean Band Pass (Spurious Response) : > 250 Hz (Typical)

DC Resistance (DCR) : 395 ohms }2.5%

Intrinsic Voltage Sensitivity (G) : 0.698 V/i/s, (0.275 V/cm/s)

Open Circuit Damping (Bo) : 0.316

Damping w/1000 ohm Shunt : 0.70 }2.5%

Sensitivity @ 70% Damping : 0.500 V/in.s, (0.197 V/cm/s) }2.5%

Moving Mass (M) : 0.395 oz., (11.2 g) }2.5%

Harmonic Distortion :

With coil to case velocity of 0.7 in/sec (1.8 cm/sec) P-P @ 12 Hz : <0.10%

String, 12 series, damped 0.70 : <0.03% (Typical)

With coil to case displacement of 0.0093 in (0.0236 cm) P-P @ 10 Hz : <0.20%

Dimensions :

Weight : 3.03 oz.(86 g)

Diameter : 1.00 in., (2.54 cm)

Height (less stud & terminals) : 1.30 in., (3.30 cm)

Specifications are subject to change without notice.