Hydrophone
MP-24.html
MP-24![]() |
![]() |
| Feature Easy method to check polarity Full one year warranty High output Acceleration noise canceling configuration |
| General Description The MP-24 is a high output, pressure sensitive detector for use in swamps, rivers, bays and transition zones. Sensitivity is approximately six times that of the GS-20DX geophone. The MP-24 is transformer-coupled and has four piezoelectric crystals connected in an acceleration-canceling arrangement with each crystal operating in the high sensitivity bender mode. The crystals and transformer are permanently molded in a durable polyurethane case. This sealed unit has a thermoplastic resin outer case with easy access ports for polarity testing. |
| Specifications Natural Frequency } 15% : 6 Hz (MP-24-L1), 8 Hz (MP-24-L2), 10 Hz (MP-24-L3), 12 Hz (MP-24-H1), 14 Hz (MP-24-H2) Voltage Sensitivity } 1.5 dB : 7.5 volts/bar (MP-24-L), 15 volts/bar (MP-24-H) Impedance : 250 ohms DC Resistance } 10% : 160 ohms Operating Temperature : 0-35C Operational Depth : 250 ft Chart for Hydrophone Response Curve Output VS. Frequency.: MP-24-L3 Dimensions: Length: 5.22 in (13.26 cm) Diameter: 2.25 in (5.72 cm) Weight: .8 in (369 g) Standard Cable Sizes: .275 and .310 in (.70cm and .79 cm) |